– 4 ETAsys.com
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
ETA-SEQ6
Sequencer Controller
Rear Panel Description
TSD Input/Output connections are removable for easy system wiring. The connectors have a 3.5mm
pitch between pins.
1. DC Power Input - Each TSD that requires DC power comes with a 2 position connector for an
external 24VDC power supply (sold separately). Because of the TSD’s low power consumption, a
single external power supply may power more than one TSD. Please refer to the specications
on current requirements in milliamps to match with the appropriate power supply. Please observe
the polarity of the wiring to this connector. Note: It is acceptable to exceed the current
requirements of the TSD but NOT safe to use a power supply that is below the current
requirement of the device. Use a power supply with a 500mA capacity (Atlas TSD-PS24V500MA).
2. Channel Output - There are 6 channel output control ports. Each output can be assigned to provide
a 24VDC output or a Hard Switch Contact Closure (CC). See the Function Settings for Output
conguration below.
3. Remote Activation Momentary Switch Port - Remote System activation can be done several
hundred feet away via a momentary contact closure type switch.
4. Remote Activation Hard Switch Contact Closure (CC) Port - Remote System activation can be
done several hundred feet away via a Hard Contact closure type switch.
5. Remote Activation 5 - 24VDC Port - Remote System activation can be done several hundred feet
away by applying 5 - 24VDC. Only a few milliamps of current is required.
6. Link Control Port - You can combine two ETA-SEQ6 units together to make a 12 step sequence
system. Note: Pay special attention to the Input and Output terminals. Connect the Output from
unit 1 (Master) to the Input of unit 2 (Slave). Connect the Output from unit 2 (Slave) to the Input of
unit 1 (Master). Pay close attention to this or the Link Out will not work. See the Function Settings
for the Master/Slave conguration below.
1 3 4 5 6 7
1010
10 10
2
8 9